Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 212-215, 2010.
Article in Chinese | WPRIM | ID: wpr-390363

ABSTRACT

Objective To investigate the correlation between intima-media thickness(IMT)and elasticity of carotid in patients with type 2 diabetes accompanied hyperlipidemia by quantitative intima-media thickness(QIMT)and quantitative arterial stiffness(QAS)technique.Methods Fifty-six patients with type 2 diabetes accompanied hyperlipidemia were involved into the study as case group.Forty-eight healthy volunteers were supplied as normal control group in the same period.IMT,compliance coefficient(CC),distensibility coefficient(DC)and stiffness index(β)of carotid were acquired through QIMT and QAS.Case group was divided into case group 1(IMT<0.9mm)and case group 2(IMT≥0.9 mm),and analysis was performed furtherly.Results β,triglyceride(TG),lowdensity lipoprotein(LDL),cholesterol(Ch),glycosylated hemoglobin(GHb)and IMT had significant differences in case group 1,case group 2 and control group(P<0.05),control group<case group 1<case group 2.DC and CC had significant differences in case group 1,case group 2 and control group(P<0.05),control group>case group 1>case group 2.There was significant positive correlation between β and age,GHb,LDL and IMT of carotid respectively(r=0.811,r:0.764,r=0.732,r:0.729,respectively,P=0.000).Conchmions IMT of carotid could be measured accurately by QIMT.Structure imaging and functional imaging of carotid might be combined organically through QIMT and QAS.Depth study about early change of carotid in structure and function could be performed with these two techniques.

2.
Chinese Journal of Ultrasonography ; (12): 382-385, 2010.
Article in Chinese | WPRIM | ID: wpr-389667

ABSTRACT

Objective To establish a quantitative measurement of flow field uniformity of mitral valve in vivo and investigate the correlation between the parameter of flow field uniformity and the degree of mitral stenosis. Methods The flow field uniformity downstream of mitral valve in normal cases and patients with mitral stenosis were studied using vector flow mapping(VFM) technique. Results The flow field uniformity parameter of standard deviation of velocity (Vsd) in patients with mitral valve stenosis was significantly higher than that in control group ( P <0. 05). There was a negative linear correlation between Vsd and effective orifice area(EOA) in patients with mitral valve stenosis (parasternal long-axis: r = - 0. 816, P = 0.000; apical four chamber: r = - 0. 825, P = 0. 000). Conclusions VFM can really reflect the flow field uniformity of normal cases and patients with mitral stenosis.

SELECTION OF CITATIONS
SEARCH DETAIL